laptop and a wrench

Bug

The Update Subnetwork tool fails and returns the error message, "ERROR 160319: Error stopping an edit session with save edits" and only succeeds after restarting ArcGIS Pro.

Zuletzt veröffentlicht: January 11, 2023 ArcGIS Pro
Bug-ID-Nummer BUG-000151971
EingereichtAugust 30, 2022
Zuletzt geändertJune 13, 2025
Gilt fürArcGIS Pro
Gefunden in Version2.9.3
BetriebssystemWindows OS
Betriebssystemversion10.0 64 Bit
Behoben in Version3.1, 2.9.7
StatusFixed

Zusätzliche Informationen

This issue is addressed in ArcGIS Pro 3.1 and 2.9.7. Running an update on all subnetworks with continuous failure after enabling the network topology can sometimes fail on a file geodatabase and return the error message, "ERROR 160319: Error stopping an edit session with save edits."

Workaround

One of the file geodatabase indexes was corrupt, causing the tool to fail. A fix is to be made in ArcGIS Pro 3.1. For ArcGIS Pro 2.9.x, the workaround is as follows:

  1. Close ArcGIS Pro.
  2. Delete the a0000001a.FDO_GLOBALID.atx file using the file explorer.
  3. Restart ArcGIS Pro and run the tool.

Schritte zur Reproduzierung

Bug-ID: BUG-000151971