laptop and a wrench

Bug

The Pan to and Zoom to commands do not work for results from custom locator services published using a coordinate system other than Web Mercator Auxiliary Sphere (3857) and added as a utility service geocoder in ArcGIS Online and consumed in ArcGIS Pro.

Zuletzt veröffentlicht: April 21, 2015 ArcGIS Pro
Bug-ID-Nummer BUG-000084857
EingereichtFebruary 3, 2015
Zuletzt geändertJune 5, 2024
Gilt fürArcGIS Pro
Gefunden in Version1.0
BetriebssystemWindows OS
Betriebssystemversion7
Behoben in Version1.1
StatusFixed

Workaround

- Project the data to Web Mercator Auxiliary Sphere, recreate the address locator, and publish the new geocoding service referencing this data.- Add in the server directly to ArcGIS Pro, and add the locator to the project.

Schritte zur Reproduzierung

Bug-ID: BUG-000084857

Software:

  • ArcGIS Pro

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen