Bug

The cluster tolerance parameter for the Planarize tool is not respected when a feature class is in a geographic coordinate system.

Zuletzt veröffentlicht: January 5, 2021 ArcGIS Pro
Bug-ID-Nummer BUG-000135935
EingereichtDecember 8, 2020
Zuletzt geändertJuly 10, 2025
Gilt fürArcGIS Pro
Gefunden in Version2.6.3
BetriebssystemWindows OS
Betriebssystemversion10.0 64 Bit
Behoben in Version2.7
StatusFixed

Workaround

  • Use a projected coordinate system (PCS).
  • Perform the following workaround if the user must work in a geographic coordinate system editing environment:
  1. Set the XY tolerance when creating the feature class. For example, 0.000106177 is about 10m, depending on the locale.
  2. Use the Planarize tool, and use the value '0' for the cluster tolerance parameter. This can bring in the XY tolerance from the feature class to be used in the tool, and provide an accurate cluster distance value for the latitude. Refer to ​​​​​​​https://pro.arcgis.com/en/pro-app/tool-reference/environment-settings/xy-tolerance.htm for more information.