laptop and a wrench

Bug

Ping failure on the Application Server Polling thread results in immediate Spatial Server restart.

Zuletzt veröffentlicht: August 25, 2014 No Product Found
Bug-ID-Nummer NIM009766
EingereichtJune 15, 2007
Zuletzt geändertApril 2, 2025
Gilt fürNo Product Found
Gefunden in Version9.2
Behoben in Version9.3
StatusFixed

Workaround

There is no workaround to resolve that issue. However, since the ping interval is defined as 1/30th the value of the recovery timeout, increasing the recovery timeout to a very large value can significantly reduce the frequency of the ping. This will reduce the opporunity for the ping to fail and should reduce the frequency of restarts. The ArcIMS recovery timeout is defined in the appserver.properties file (located in %AIMSHOME%\appserver) and has a default value of 300 seconds. Thus the default interval for the AppServer ping is every 10 seconds.

Schritte zur Reproduzierung

Bug-ID: NIM009766

Software:

  • No Product Found

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen