laptop and a wrench

Bug

In ArcGIS ArcObjects 10, when IGeodesicNewLineFeedback SpatialReference is set to a non-null value, the IDisplayFeedback MoveTo behavior changes so that it reprojects input points to the World Mercator coordinate system.

Zuletzt veröffentlicht: August 31, 2014 ArcGIS for Desktop
Bug-ID-Nummer NIM065289
EingereichtFebruary 17, 2011
Zuletzt geändertJune 5, 2024
Gilt fürArcGIS for Desktop
Gefunden in Version10.0
ProgrammspracheC#
BetriebssystemWindows OS
BetriebssystemversionXP
StatusWill Not Be Addressed

Zusätzliche Informationen

We apologize that we were unable to address this issue within the current product support cycle. If the issue continues to affect your work in a supported release, please contact Technical Support.

Workaround

Clone the point prior to using the MoveTo method://feedback.MoveTo(mapPoint);feedback.MoveTo((IPoint)((IClone)mapPoint).Clone());