Bug

Communications Utility Network Foundation Solution is encountering the "Error 001797: No valid subnetwork controllers found" error while following the task to perform the 'Customer to upstream Switch' trace.

ArcGIS Pro
Bug-ID-Nummer BUG-000167050
EingereichtApril 26, 2024
Zuletzt geändertJuly 9, 2024
Gilt fürArcGIS Pro
Gefunden in Version3.2.2
BetriebssystemWindows OS
Betriebssystemversion10.0 64 Bit
StatusIn Product Plan

Zusätzliche Informationen

The task calls the models in Communications Trace toolbox. These models leverage the Utility Network Trace GP Tool. The Starting Points input must be mapped to Trace Features\Starting Points but is incorrectly pointing to Wire Cabinets. Adjust the Starting Points input and the task and model succeeds.

Workaround

In the Communications Traces toolbox, open each model and adjust the Starting Points input to point to Trace Features\Starting Points.

Schritte zur Reproduzierung

Bug-ID: BUG-000167050

Software:

  • ArcGIS Pro