laptop and a wrench

Bug

After updating to Business Analyst 9.3.1, clients get the GXImageConnect error message when opening Business Analyst.

Zuletzt veröffentlicht: August 25, 2014 ArcGIS for Desktop
Bug-ID-Nummer NIM047584
EingereichtAugust 19, 2009
Zuletzt geändertMay 12, 2025
Gilt fürArcGIS for Desktop
Gefunden in Version9.3.1
Behoben in Version9.3
StatusFixed

Workaround

Fix the paths in the registry to include Program Files. From the registry: HKEY_LOCAL_MACHINE\SOFTWARE\GlobeXplorer\ImageConnect\ArcGIS9.Both the AppPath and HelpFile keys need to be amened to include the "Program Files" part of the path.AppPath goes from C:\ArcGIS\Bin to C:\Program Files\ArcGIS\BinHelpFile goes from C:\ArcGIS\Business Analyst\Documentation\ImageConnect for ArcGIS.pdf to C:\Program Files\ArcGIS\Business Analyst\Documentation\ImageConnect for ArcGIS.pdfMaking this registry change will fix the path and the client will no longer get the message.

Schritte zur Reproduzierung

Bug-ID: NIM047584

Software:

  • ArcGIS for Desktop

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen

Weitere Informationen zu diesem Thema erkunden

Unterstützung durch ArcGIS-Experten anfordern

An den technischen Support wenden

Esri Support App herunterladen

Zu Download-Optionen wechseln