laptop and a wrench

Bug

After installing ArcGIS Server 10.8.1 Utility Network Patch 6, the Validate Network Topology tool returns the message, "ERROR 002981: Value exceeds valid range of column".

Zuletzt veröffentlicht: March 3, 2022 ArcGIS Utility Network
Bug-ID-Nummer BUG-000147284
EingereichtMarch 2, 2022
Zuletzt geändertJanuary 26, 2026
Gilt fürArcGIS Utility Network
Gefunden in Version4
BetriebssystemWindows OS
Betriebssystemversion10.0
StatusNon-Reproducible

Zusätzliche Informationen

The last reproducible case of this failure occurred in Utility Network patches for ArcGIS Enterprise 10.8.1. As of the 10.9.1 release, this failure is no longer encountered. ArcGIS Enterprise 10.8.1 is no longer supported. Move to a supported release if encountering this failure.

Workaround

  • When network topology validation fails, disable and re-enable network topology to get the Validate Network Topology tool to run successfully.
  • Remove ArcGIS Server 10.8.1 Utility Network Patch 6 and install ArcGIS Server 10.8.1 Utility Network Patch 5B.

Schritte zur Reproduzierung

Bug-ID: BUG-000147284

Software:

  • ArcGIS Utility Network

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert