laptop and a wrench

Bug

After failover, if an incremental backup is requested but a full backup has not been run, run a full backup instead of an incremental.

Zuletzt veröffentlicht: April 25, 2022 Portal for ArcGIS
Bug-ID-Nummer BUG-000124785
EingereichtAugust 26, 2019
Zuletzt geändertJune 5, 2024
Gilt fürPortal for ArcGIS
Gefunden in Version10.6.1
BetriebssystemWindows OS
Betriebssystemversion2016 64 Bit
Behoben in Version10.8
StatusFixed

Workaround

There are 2 workarounds:

  • Set the backup location to a shared location. Since both data store machines can access the backup location for the data store that stores incremental snapshots, they are able to avoid issues when an incremental backup is requested after a failover.
  • Run a full backup manually. Note that if the backup location is not in a shared location that both data store machines can access, the issue may occur if the data store needs to failover again.

Schritte zur Reproduzierung

Bug-ID: BUG-000124785

Software:

  • Portal for ArcGIS

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen