laptop and a wrench

Bug

A flat voxel is generated when an input study area polygon is used in the GA Layer 3D To NetCDF tool.

ArcGIS Pro
Bug-ID-Nummer BUG-000160854
EingereichtAugust 23, 2023
Zuletzt geändertNovember 22, 2025
Gilt fürArcGIS Pro
Gefunden in Version3.1.2
BetriebssystemWindows OS
Betriebssystemversion10.0 64 Bit
Behoben in VersionArcGIS 3.6
StatusFixed

Zusätzliche Informationen

This issue is addressed in ArcGIS Pro 3.6.

Workaround

Convert the study area polygons to a 2D polygon feature class without Z-values. Use the Feature Class To Feature Class geoprocessing tool. In the Environments tab, set 'Output has Z Values' to 'Disabled' (found in the 'Z Values' group). Then provide the 2D polygons as the study area polygons in the GA Layer 3D To NetCDF tool, and provide any desired values for the 'X spacing', 'Y spacing', and 'Elevation spacing' parameters.

Schritte zur Reproduzierung

Bug-ID: BUG-000160854

Software:

  • ArcGIS Pro

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen

Weitere Informationen zu diesem Thema erkunden

Unterstützung durch ArcGIS-Experten anfordern

An den technischen Support wenden

Esri Support App herunterladen

Zu Download-Optionen wechseln