laptop and a wrench

Bug

3-tier connection from ArcCatalog to native 64-bit SDE hangs in a Windows 2003/2008 64-bit server environment.

Zuletzt veröffentlicht: August 25, 2014 No Product Found
Bug-ID-Nummer NIM048382
EingereichtSeptember 21, 2009
Zuletzt geändertJune 5, 2024
Gilt fürNo Product Found
Gefunden in Version10.0
Behoben in VersionN/A
StatusFixed

Workaround

1. Open CMD prompt2. Type set SDEFORCEXDR=13. Type in same CMD windows "C:\Program Files (x86)\ArcGIS\Bin\ArcCatalog.exe" to open ArcCatalog4. Create an sde database connection without fully qualifying the server nameRESULTS: Connection will be successful.b) Also setting SDEFORCEXDR=0 also resolved the issue.c) Another workaround was to provide fully qualified domain name with server name or IP Address in the Server column in Spatial Database Connection.

Schritte zur Reproduzierung

Bug-ID: NIM048382

Software:

  • No Product Found

Benachrichtigung erhalten, wenn sich der Status eines Bugs ändert

Esri Support App herunterladen